Better Planet was appointed to design, supply, install and commission a ground source heat pump system for this manor house in Cambridgeshire previously heated by an oil boiler.

Better Planet did a room by room heat loss calculation required to size the heat pump and the ground collector correctly. We also provide a draft EPC allowing us to accurately predict payments under the domestic RHI scheme.

Project summary:

  • A Nibe F1345 – 30kW ground source heat pump
  • Five ground loops, 400 m each, 40mm pipe
  • A ground manifold
  • 63mm flow and return pipes between the manifold and the plant room
  • A 300 litre heat pump cylinder
  • A 500 litre buffer tank